IR-BA Series High-speed Compact Radiation Thermometers

IR-BA series is relatively low-priced compact infrared radiation thermometer with emissivity compensation and measured value analog output. Its compact card size does not take much installation space, so that allows easy and convenient installation into the system. Indicator with power supply is also available for supplying power and displaying measured value. Our broad lineup of products are followings: standard type, small target/short distance type, and small target/long distance type for each general and high-speed (95% response at 50ms) models, and glass type, lamp anneal type, film type, and burning gas type for various application models.

 

Models

FOR GENERAL

Types Models Measuring Range
Standard IR-BAT1A 0 to 300°C
IR-BAT1B 0 to 600°C
Small Target/Short Distance IR-BAT2A 0 to 300°C
Small Target/Long Distance IR-BATSA 0 to 300°C
IR-BATSB 0 to 600°C

FOR HIGH-SPEED

Types Models Measuring Range
Standard IR-BAT1M 0 to 300°C
IR-BAT1P 0 to 600°C
Small Target/Short Distance IR-BAT2M 0 to 300°C
Small Target/Long Distance IR-BATSM 0 to 300°C
IR-BATSP 0 to 600°C

FOR APPLICATIONS

Types Models Measuring Range
For Glass IR-BAXG1 100 to 400°C
For Lamp Anneal IR-BAXL1 400 to 1300°C
For Polyethylene Film IR-BAXF1 80 to 250°C
For Polyethylene Film IR-BAXF2 50 to 150°C
For Burning Gas IR-BAXH1 500 to 1300°C

Specifications

Accuracy Rating Below 300°C±3°C
For 300°C or more, ±1.0% of the measured value
*However, ε=1.0 at reference operating condition
For various application use, it differs depending on the object to be measured.
Repeatability ±0.2°C (0 to 300°C), ±0.3°C (0 to 600°C)
Resolution 0.2°C (0 to 300°C), 0.5°C (0 to 600°C)
Response Time For general=100ms, foe high-speed=50ms (95% response each)
For various application use, it differs depending on the object to be measured.
Optical System Ge lens
Measuring Diameter/
Measuring Distance
Standard type φ40 (500mm)
Small Target/Short Distance type φ5 (80mm)
Small Target/Long Distance type φ40 (1000mm)
For various application use, it differs depending on the object to be measured.
Emissivity Compensation ε=1.99 to 0.10 (Digital switch)
Analog Output 4 to 20mADC (Load resistance 280Ω or less)
Working Temperature Range 0 to 50°C
Power Supply Voltage 12 to 24V DC
Current Consumption 60mA or less
Connecting Cable Length Standard 2m (Max. 200m with extension cable)
Case Aluminum die-casting
External Dimensions W32×H56×D100mm
Weight Approx. 220g

*For other specifications, refer to the catalog.