Data Logger FE (Japan Only) 

The FE series is a data logger that configuration of modules with the functions of "analog input", "digital input", "digital output", "communication" and "power supply". You can build a flexible system by combining modules according to the needs of the site. It supports device setting and real-time monitoring via a web browser.
Introducing the "high-speed full multi-input" specifications that supports high-speed 10 ms recording and a wide variety of sensor inputs!

Experience operation the FE series web browser.
Click here for the public page

Remote monitoring made easy

Various sensors connected to production equipment and environmental sensors in storage facilities and offices can be monitored in real time using a web browser on a PC or tablet.
This makes it easy to build a remote facility monitoring and data acquisition system.
Remote monitoring made easy

Flexible configuration customization

Up to 10 analog input, digital input and digital output modules※1Can be connected. The number of inputs and outputs can be increased by adding modules.
Data measured via analog input, such as thermocouples, resistance thermometer, DC voltage, and standardized instrumentation signals, is recorded on an SD card (sold separately) in the communication module.

FE10台まで連結
*1 If there is a "digital output" or "high-speed full multi input" in the unit, a maximum of 8 units are available.
*2 high-speed Full Multi specifications is 4 points/unit

High accuracy, high-speed and diverse input

  • Analog input modules are measured to within 0.05% of reading
  • High accuracy actual value (measurement accuracy of K thermocouple: ±0.2℃, etc.)
  • High insulation between input channel
  • Supports a wide variety of inputs, including 4-wire resistance thermometer※3
  • Fastest 10ms/Supports up to 32 channel※3
*3 "high-speed full multi-input" specifications

Smooth integration with PLC

SLMP communication that connects PLC*3 and FE series without programming
Supports Modbus/TCP client that records input data from Modbus devices (such as SB and KR) in FE.
This reduces the time required to build an acquisition system.

Smooth integration with PLC

Specifications

Model List

Product name Models
Communication Module FE1CMN0-000-NNN
Analog Input Module FE1AX - -NNN
Digital Input Module FE1DX16-00P-NNN
Digital Output Module FE1DY08-003-NNN
Power Supply FE1PS00-000-NNN

Communication Module Specifications

Measurement specifications 10ms/25ms/50ms/100ms/200ms/500ms/1s/5s
Number of measurement points 100 points (10 analog input modules)
External recording media SD card (up to 32GB)
recording intervals Standard: 100ms to 60 minutes, high-speed: 10ms to 60 minutes
Communication interface Ethernet (100BASE-TX)
Communication protocol FTP, HTTP, Modbus/TCP, SLMP, MQTTs
Others Alarm…4 settings, DI…1 point, DO…1 point

Analog Input Module Specifications

Input Signal Thermocouple/ resistance thermometer / DC voltage /unified signal for instrumentation
Accuracy ratings ±0.05% of rdg ±0.6℃ (for K thermocouple. For other details, please refer to the catalog)

Digital Input Module Specifications

Input Type DI or Pulse
Number of input points 16 points COM common

Analog Input Module Specifications

Model high-speed full multi-input Full multi-input Thermocouple Voltage Input
Number of measurement points 4点 10点
Measurement Interval 10ms, 25ms, 50ms
100ms, 200ms, 500ms, 1s, 5s
100ms, 200ms, 500ms, 1s, 5s
Input Type Thermocouple/ resistance thermometer (3-wire/4-wire)/
DC voltage /unified signal for instrumentation
Thermocouple/ resistance thermometer (3-wire type)/
DC voltage /unified signal for instrumentation
Thermocouple/ DC voltage /Unified signal for instrumentation
Accuracy ratings ±0.05% of rdg ±0.6℃ (for K thermocouple. For other details, please refer to the catalog)

Power Supply Module Specifications

Power supply 100 to 240 VAC (50/60 Hz)

Download Documents

Catalog

Specification Sheet (PS Sheet)

Specification Sheet (PS Sheet) (English)

Instruction Manual

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • Data Logger FE Series [General]
    ファイルサイズ13MB
    Models
    FE
    Document No.
    FE-01-1
    Downloads
  • Data Logger FE Series Precautions for Use [Installation]
    ファイルサイズ1MB
    Models
    FE
    Document No.
    FE-02-2
    Downloads

Instruction Manual (English)

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • English)Data Logger FE Series Precautions for use [Installation]
    ファイルサイズ1MB
    Models
    FE
    Document No.
    FE-02-2
    Downloads

Software

CAD Data

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • FE1AX, FE1DY (2DCAD/dxf file) *FE1AX and FE1DY have the same shape
    ファイルサイズ1MB
    Downloads
  • FE1AX, FE1DY (3DCAD / igs file) *FE1AX and FE1DY have the same shape
    ファイルサイズ5MB
    Downloads
  • FE1AX, FE1DY (3DCAD / step file) *FE1AX and FE1DY have the same shape
    ファイルサイズ3MB
    Downloads
  • FE1PS (2D CAD/dxf file)
    ファイルサイズ1MB
    Downloads
  • Link FE1PS, FE1CM, and FE1AX (3DCAD/igs files)
    ファイルサイズ11MB
    Downloads
  • Link FE1PS, FE1CM, and FE1AX (3DCAD/step file)
    ファイルサイズ6MB
    Downloads
  • FE1CM (2D CAD/dxf file)
    ファイルサイズ1MB
    Downloads
  • FE1DX (2D CAD/dxf file)
    ファイルサイズ1MB
    Downloads
  • FE1DX (3DCAD/igs file)
    ファイルサイズ5MB
    Downloads
  • FE1DX (3DCAD/step file)
    ファイルサイズ3MB
    Downloads

Application Examples

Related Info

Movie

  • (1) Open the WebApp from the Communication Setup
  • (2) Overview of WebApp
  • (3) Check the measurements in real-time trends

FAQ

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.

You must be a login to download.