Chapter 1
This page will be helpful for
- Site supervisors and construction managers want to streamline temperature monitoring during concrete curing.
- Quality control personnel who want to keep a record of temperature history and use it for sharing and reporting.
- Those who want to review their temperature control methods during winter construction
- For those considering a temperature logger that is easy to use in the field.
Chapter 2
Why is temperature control important in concrete curing?
When monitoring the temperature during concrete curing, it is important not only to measure the temperature but also to check the condition at necessary times, record the history, and share it with relevant parties.
Especially during winter construction, concrete temperature control is crucial for ensuring construction quality. On-site, this involves not only the measurement itself, but also tasks such as moving equipment to check temperatures, collecting data, organizing records, and preparing reports.
Specific temperature control methods and standards for concrete curing vary depending on construction conditions, structure, and construction specifications. This page focuses on the operation of equipment for recording and verifying temperature history.
Chapter 3
Common problems with temperature recording during concrete curing
data logging takes time.
In operations where data is checked and transcribed manually, the burden increases as the number of measurement points and the number of recordings increase.
It is difficult to check the history on-site.
In operations where data is collected and then reviewed, it can be difficult to make on-the-spot decisions at the site.
Preparing reports is time-consuming.
In some cases, it may be necessary to organize the collected data separately and compile it into a report.
Setting up and retrieving the logger becomes complicated.
For equipment used in the field, it's also important that operation, from the start of measurement to data retrieval, is easy to understand.
Chapter 4
Points where the MR532N is useful for recording temperature during concrete curing
1. Easy to check the recorded temperature history on the spot.
Temperature data recorded with the MR532N can be transfer to a smartphone via NFC communication. features it easy to check temperature history on-site and simplifies the verification process after data retrieval.
2. Recording, transfer, and checking can be easily done primarily using a smartphone.
The dedicated app allows you to check the status, start recording, stop recording and acquire data, view a list of recorded data, configure device settings, set a passcode, and initialization the logger.
Recording can be started immediately, or scheduled, allowing you to set start and end times.
3. Easily connects to sharing and reporting tasks.
The measurement data can be display in CSV and models models You can also access the recorded data by connecting your smartphone to your PC via USB, configuration easy to use for data sharing and reporting.
Chapter 5
Points that are easier to review compared to conventional temperature records
| Comparative perspective | Conventional operation | When using MR532N |
|---|---|---|
| Check temperature history | This may be checked after collection or during other tasks. | Easy to check by holding your smartphone over it. |
| operational load | It can be time-consuming to check, organize, and share. | Recording, transfer, and checking can be easily done using a smartphone. |
| Report support | Further processing may be required. | Supports display reports in CSV/PDF models. |
| Ease of use on site | The verification process and data collection may be complex. | NFC communication and smartphone apps are available. |
Chapter 6
Main features of MR532N
- Simply hold your smartphone over it to obtain temperature measurement data from a T-type thermocouple.
- Alarm settings can be configured via a smartphone app.
- When an alarm is triggered, the LED on the logger unit display flash.
- Recording settings can be configured via a smartphone app.
- 2000 data points collected in approximately 10 seconds.
- Battery life approximately 2000 hours (depending on conditions)
- Recorded data is retained even if the battery runs out
- Measurement data display in models and PDF models.
- The thermocouple is connected with a one-touch lighting connector.
- Smartphone-centric operation is possible.
The MR532N is not exclusively for concrete curing. It can also be used for a wide range of temperature control applications, including refrigeration, freezing, environmental measurement, and testing and research equipment.
Chapter 7
What you can do with a smartphone app
| function | Contents |
|---|---|
| Status check | Check the current status and temperature of the device. |
| Recording begins | Set the recording interval, start date and time, and end date and time, then start recording. |
| Recording complete / Data acquisition | After recording stops, a summary of the saved data display |
| List of included data | display a list of saved data, send an email, delete data. |
| Device settings | Set the equipment name, group number, project name, alarm, offset, channel name, etc. |
| Passcode setting | Set the passcode required for logger operation. |
| Logger initialization | initialization to shipment settings |
The recording method supports "same-day recording," which starts immediately, and "scheduled recording," which allows you to set start and end times.
Chapter 8
Key specifications of MR532N
| Models | MR532N |
|---|---|
| Input sensor type | T-type thermocouple (allowable signal source resistance of 600Ω or less) |
| Number of input points | 2 channel /unit |
| Temperature Sensor Measurement Range | -50℃~150℃ |
| Main unit operating temperature range | -10℃~50℃ |
| Humidity range for use with the main unit | 10%RH to 80%RH (non-dew condensation) |
| Main body waterproof | IP64 |
| battery | Two AAA alkaline batteries |
| Battery life | Approximately 2000 hours (at 25°C, with a data recording interval of 10 minutes) |
| Accuracy ratings | ±(0.1% of the measured value + 0.3°C) (ambient temperature 25°C) |
| Reference contact compensation accuracy | ±0.4℃ (ambient temperature 15-35℃) ±0.7℃ (ambient temperature -10 to 15℃ / 35 to 50℃) |
| Number of recorded data | 10,000 data/CH |
| Data recording interval | 1 minute to 24 hours (default value: 10 minutes) |
* specifications are subject to change. Please refer to the latest product specifications before implementation.
FAQ
Frequently Asked Questions about MR532N
Is the MR532N specifically for concrete curing?
This is not a specialized product. It's a smart card logger that can be used for a wide range of applications, including refrigeration/freezing, environmental measurement, and testing/research equipment. This page specifically focuses on its use in concrete curing temperature management.
How do you verify the data?
The recorded temperature data can be transfer to a smartphone via NFC communication for viewing. Reports can also be display in CSV and models models
What types of sensors can be connected?
Two T channel thermocouples can be connected. Connection is made via a one-touch lighting connector.
Will the data be lost when the battery runs out?
The device is specifications to retain recorded data even when the battery runs out.
Which part of the concrete should I measure?
The measurement location and method will vary depending on the construction specifications, construction conditions, and required temperature control methods. Instead of setting a uniform location, please confirm and set the location based on the required control methods at the site.
What should I check before deploying the system in the field?
Checking the measurement range, operating temperature and humidity range of the device, recording interval, thermocouple to be used, compatible devices for the app, and data sharing method in advance will make it easier to design the operation.
For those who want to review their concrete curing temperature records.
For information on the MR532N's specifications, usage in concrete curing applications, measurement methods, and data handling, please refer to the product documentation.
Please contact us if you would like to discuss temperature measurement tailored to your specific site conditions.
Download the catalog for concrete curing.I want to discuss temperature control.